Pre-release SerialFlow 0.9.0 beta 2 works, but has rough edges. Tell us what you find.

Pre-release · 0.9.0 beta 2 · 24 Nov 2026

Plug in. Pick the port. It logs.

The serial terminal that grows with your bench: colour logs, real-time graphs and live dashboards from your firmware's serial output.

Free · Windows 11, 64-bit (Windows 10 should work, not yet tested) · one installer, .NET built in

Animation: the full SerialFlow workspace with a scrolling log, a speed graph stepping and three-phase currents updating.

Performance

Built to outrun your serial port.

At 3 000 000 baud, a serial link delivers about 5 400 log lines a second. SerialFlow can take in over 800 000.

Log lines per second
  • SerialFlow 800 000+
  • 3 000 000 baud 5 400
  • 921 600 baud 1 700
  • 115 200 baud 210

Log lines of about 55 characters. A serial rate is the most its link can carry. SerialFlow’s figure is its parser and log on one core of an Intel Core i7-13700K, in the slowest case we measured.

  • Never holds up the port

    Data is read and sorted in the background, so a busy window can’t slow it down.

  • Smooth at full speed

    The log only draws what’s on screen. A graph fits a million points into each redraw in about 2 ms, without losing a spike.

  • Runs for days

    Fixed limits keep memory in check. If data is ever dropped, the status bar tells you.

A UART logger that fits beside your IDE

Compact, but complete.

Most of the time you just want to see what the board is saying. SerialFlow runs happily as a small window: one terminal, one tool strip and a send line. It shows full ANSI colour, and adds timestamps and line numbers when you want them. Press Ctrl+F to find anything, mark keywords in your own colours, and log to a file while you watch. Everything else stays out of the way until you need it.

  • Full colour straight from your firmware’s ANSI codes: 16, 256 or 24-bit
  • Timestamps and line numbers from SerialFlow, from your firmware, or both side by side, so a lost or late line stands out (how it works)
  • Find with a match counter: every match is highlighted, the current one in orange, and F3 / Shift+F3 (or Enter / Shift+Enter) step through them all (case, whole-word and regular-expression options)
  • Keyword highlighting: TRIP in red, WARN in amber, your own rules
  • Quick Send buttons and macros, right under the log
  • Log to .txt or .csv while you watch (arrival times in the CSV log, and in the text log if you like), or auto-log every session to a folder with size and file-count limits
  • 100 000 lines of scrollback by default (configurable)
  • A layout that bends to your desk: every window is drag and drop. Dock it, stack it as a tab, or float it on its own, even onto a second or third monitor
Animation: a compact SerialFlow window filling with a colour-coded log line by line.
A simple UART logger that keeps up: colour and keyword highlighting as the data arrives, with SerialFlow’s timestamps and line numbers switched on.
Three small SerialFlow windows showing the same motor-drive log: without timestamps and line numbers, with both switched on, and with the find bar and four highlighted matches.
Left: timestamps and line numbers off, only what the device sent. Middle: both switched on, added by SerialFlow. Right: Ctrl+F, every match highlighted, F3 to step (2 / 4). How it was done →

Starts as a simple logger, and grows into a full workspace when the job does.

A small SerialFlow log window beside a full-screen SerialFlow workspace with graphs and status windows.

Your firmware's output, exactly as it prints it

A terminal that speaks your firmware.

What you see here is drawn by the firmware itself. No layout file, no plug-in, nothing to set up in SerialFlow: the board prints, and the screen follows.

Colour works the way your firmware already prints it. Standard ANSI codes colour the text and its background. Box-drawing and block characters become frames, rules and bars. Pictures marked From firmware show nothing but what the board printed.

  • 16, 256 and 24-bit colour, for the text and for its background
  • Bold, italic, underline and strikethrough
  • Box drawing and block characters ( ╔ ═ ╗ ─ ░ ▒ ▓ █ ) for frames, rules and bars
  • Cursor moves, line clears and \r work as on a real terminal, so a progress line redraws in place
  • Short colour tags such as <R>…</R> and <G>…</G> where an ANSI code is too long
Dark terminal with a boxed MDX-400 boot banner, colour-coded status levels and colour gradient bars.
From firmware Boot banner, status levels and colour bars: all ANSI codes in the firmware’s own output.

Status windows: a live dashboard made of text

Print one line, and one row of a dashboard changes. ~WrLi1:4:Speed 2594 rpm writes row 4 of status window 1. The next line for row 4 replaces it, and nothing else moves. The window opens by itself the first time the firmware names it, and it stays put however fast the log scrolls beside it.

printf("~WrLi1:3:State   \x1B[1;92mRUN\x1B[0m\n");
printf("~WrLi1:4:Speed   %5d rpm\n", rpm);
printf("~WrLi1:8:MOSFET  %5.1f C  %s\n", t, bar);

The layout, the colours, the bars and how often they change: all of it lives in your firmware. SerialFlow only draws what arrives.

Animation: a text status table with speed, torque and a MOSFET temperature bar changing colour.
From firmware Window 1 of the drive, written by lines like these. The MOSFET bar changes colour as it heats. How it was done →
  • Up to 9 windows per port. Each opens as its own tab the first time the firmware names it. Dock it beside the log, or stack several.
  • Any row, in any order. Write row 12 before row 0. Rows you never write stay empty.
  • Only the changed row travels. A 25-byte row update means about 460 refreshes a second at 115 200 baud, and still about 38 at 9 600.
  • Colour per word. Text and background colours make status badges: a green RUN, a red TRIP.
  • Bars and gauges in text. Repeat █ up to the value and colour it by level. The firmware decides it all.
  • Insert, delete or clear a row, or clear the whole window, when the device changes mode: ~InLi1:3:…, ~DeLi1:3, ~ClL1:5, ~ClA1:. Inserted and deleted rows push the ones below down or pull them up.
  • One stream for everything. Log lines, graph lines and status rows share one serial output, and SerialFlow sorts them.
  • Plain printf, no library. Any MCU, RTOS or language that can print a line of text.
Animation: 13 battery cell voltages, each with a coloured bar showing its balance against the pack average.
From firmware Window 2: 13 cell voltages with balance bars, sagging under load. Sixteen rows, one firmware.
Animation: three status-window tabs are dragged one at a time onto the dock guide and dropped under the log and beside each other: drive status, battery pack and motor control, all updating while the log scrolls above.
All three at once: drag a window’s tab onto the dock guide and drop it under the log or beside another window. They keep updating while you arrange them.

On the PC side

Tools that work on any output, whether the firmware uses commands or not: keyword colours, a hex view, bookmarks with notes, and Raw Display, which shows the command lines themselves while you write your firmware.

Real-time graphs from one line of text

Serial.println → graph.

Graphs need no plug-in and no binary protocol. The firmware prints one line to set up a graph, one line per signal, then one short line per sample. SerialFlow opens the graph as soon as it sees the first line.

~{A:I:Sensors:500:S:T:F:Sample::0}        create graph A: "Sensors", streamer, 500 points
~{A:S:1:F32:R:Temperature:C:0:FF6644}     signal 1: temperature, °C, orange
~{A:S:2:F32:R:Humidity:%:0:44AAFF}        signal 2: humidity, %, blue
~{A:1:23.5:67.2}                          one sample of both signals

That is the whole setup, and it lives in the firmware. Its lines can set everything about a graph:

  • its title and mode
  • the signal names, colours and units, with SI scaling so millivolts show as volts
  • the Y and X ranges, the axis labels and the legend, and 1:1 axes for XY plots
  • limit lines, event markers, bookmarks and notes

Connect, and the graphs build themselves. The firmware also chooses whether to add a CRC-8 to each line, and whether to use the packed binary mode for high-rate data: COBS-framed packets with a CRC-8, carrying many samples each at full precision.

Three modes

Animation: three sine-wave phase currents growing in amplitude.

From firmware

Frame

An oscilloscope view: the firmware sends a full frame and SerialFlow swaps it in at once.

How it was done →

Animation: a rounded six-lobed current vector shape growing and turning.

From firmware

Frame as XY

Plot one signal against another, for example a motor’s current vector. The data alone picks XY; there is no switch. Fix both axes and draw them 1:1, and a circle stays round.

How it was done →

Measure, compare, zoom

On the PC side, for any graph, however the firmware set it up:

  • 26 graphs per port, up to 32 signals each, plus computed signals
  • Pop Out a graph into its own window for a second monitor, or show it Full Screen, in one click
  • Overlay or stacked lanes, each lane with its own Y axis
  • X and Y marker pairs with Δ, frequency and range statistics
  • Live statistics for every signal (min, max, average, RMS, standard deviation, peak-to-peak), and for a selected region
  • Select a region to zoom to it, crop it or open it in a new view
  • Display averaging: see the signal under the noise without changing the stored data (9 display modes)
  • Compare runs: lay a saved session over today’s data
Graph with a shaded X marker band and Y marker lines, beside a panel of measured values.
Marker pairs with Δ, frequency and range statistics. How it was done →
Two graphs: a noisy orange current trace on the left, the same trace smoothed on the right.
Display averaging: see the signal under the noise, without changing the data.

Build an HMI in minutes

From numbers to a control-room view.

Animation: a dark dashboard with battery, inverter and motor panels; gauges and trend lines move, a warning banner turns orange.
Gauges, bars, indicators and sparklines bound to live signals. How it was done →

Put widgets on a canvas, drag them into place and bind them to any live signal: gauges, level bars, sparklines, value displays, banners and shapes. Thresholds colour a widget when a value crosses a limit, and can sound an alarm. The canvas stays live while you edit it, and opens again where it was after a restart. If you only need a quick look, pick signals and get an instant grid dashboard instead.

Give the canvas a picture to sit on: a photo of the boiler, a drawing of the machine, or the board’s PCB. Put each gauge where its sensor is, and anyone can see at a glance what a number means.

The values come straight from the firmware’s graph lines. The layout is the one part you build on the PC, once.

  • 67 canvas widget types in 8 groups (numeric, gauge, status, chart, text, shape, specialised, control), pictures included: from gauges and trend charts to a traffic light, an annunciator panel, a heat grid and an artificial horizon
  • Controls: a button, a switch, a slider and a number box that send a command to the board, such as SET {value}: only in run mode, only while the port is open, and they ask first
  • A background picture behind the widgets (PNG, JPG or BMP), with its own opacity and stretch, or a gradient fill
  • Thresholds on every widget: an alarm banner turns amber at 72 °C and red at 78 °C
  • Alarms: watch the value, or its average, minimum or maximum over the last seconds; wait before triggering; play a WAV or MP3 sound until someone clicks Acknowledge
  • Charts with a grid, values and titles on their axes, a time axis in seconds and a fixed or shared scale; the XY Plot draws one signal against another
  • 100 undo steps, resize handles, a grid and Align (line up or space out the selected widgets) in edit mode
  • Describe a dashboard as text, for example written by an AI assistant, and import it in one step
  • Take a canvas to another PC in one .sfcanvas file, pictures included
  • Grid Signal Dashboard with 8 tile types, for when you don’t want to design anything
  • Its own screen: Pop Out moves the dashboard into its own window for a second monitor, Full Screen maximises it there: a control-room view beside your IDE
Thresholds tab with two colour levels.
Thresholds change colour when a value crosses a limit. How it was done →
Animation: a canvas dashboard drawn over a picture of the MDX-400 bench (battery pack, inverter board, BLDC motor and brake). Pack voltage, power, speed, current, temperatures and torque change live at the end of each sensor's leader line, and DERATE lights up as the MOSFET heats.
A canvas on a background picture: each value sits where its sensor is. The drawing is a plain PNG, set in Canvas Properties.

From raw counts to real units

Send raw ADC counts. See volts, amps and degrees.

Simple scaling can come from the firmware itself: a signal sent in millivolts and declared with SI prefix −3 shows in volts, with nothing to set up. For anything more, keep the firmware simple and do the maths on the PC. Give each signal a scale, offset and unit, and the graph shows engineering units. Computed signals combine others, so DC power = pack voltage × current appears as its own trace. Value-range rules hold, clamp or discard impossible samples before they reach the graph.

  • Unit conversion per signal: scale, offset, unit
  • Computed signals: derive power, differences or ratios on the fly
  • Value-range rules: hold, clamp or discard out-of-range samples
Three-lane graph: voltage, current and computed power.
Computed signals: DC power = pack voltage × current, as its own trace. How it was done →

Buttons, macros and auto-replies

Stop typing the same command twice.

Row of coloured buttons: START, STOP, RPM 1500, RPM 2200, RPM 3000, FAULT RESET, STATUS.

Put your commands on coloured buttons: START, STOP, RPM 2200, FAULT RESET. One button can send several lines with delays between them. Macros run a whole sequence, can wait for the device’s answer before the next step, and start from a keyboard shortcut. Auto-reply answers the device on its own when a line matches plain text, hex or a regular expression.

  • Quick Send buttons in your own colours, with multi-line sends and delay: steps
  • Macros with send, delay and wait-for-answer steps, repeat counts and a keyboard shortcut each
  • Auto-reply rules: plain text, hex or regex, with a delay, a one-shot option and a match count that updates live
  • Macros and rules imported and exported as JSON
  • Send history, hex sending and a choice of line ending
Edit Quick Send Button dialog.
One button can send several lines with delays. How it was done →

Find out what went wrong on the wire

When the link misbehaves, see why.

Every graph line that fails its CRC, is cut off or is malformed is collected with its reason, so a noisy cable shows up as a list of errors, not as a graph that quietly looks wrong. The checksum calculator computes CRC, sum and hash values for any text or hex input.

  • RX Error Collector, sorted by category (CRC, structure, command, format)
  • 12 checksum and hash algorithms: CRC-8, CRC-16 (CCITT, Modbus, XMODEM), CRC-32, LRC, XOR, Sum8, Sum16, MD5, SHA-1, SHA-256
  • Which adapter is on which COM port: see Port Details below
Table of rejected frames with categories and reasons.
Every rejected frame is collected and explained. How it was done →
Three checksum calculator panels: the algorithm list, a CRC-8 result and a SHA-256 result.
A built-in checksum calculator: CRC, sums and hashes. How it was done →

Record everything, keep everything

Every signal, every port, one recording.

Press Record and the Data Collector writes every graph signal from every open port into one dataset: SQLite, CSV, JSON Lines or any combination. Events such as connects, bookmarks and markers are written with the samples. Save a graph as a .sfplot session (data, notes and view in one file) and reopen it later, or send it to a colleague. Export any graph, or just a selected range, for Excel, Python or MATLAB.

The firmware can keep the evidence itself. Tick one box in Settings, and when the board decides something is worth a look, ~{A:W:stall} saves what graph A shows at that moment and ~SvLog:stall saves the log. ~LogOn and ~RecOn start the Data Logger and the Data Collector. The Saved Captures pane lists every file and opens it.

  • Data Collector: SQLite, CSV, JSON Lines; auto-start on connect and auto-stop on the last disconnect
  • The serial port is never slowed down by the disk: samples are queued and counted if any are dropped
  • Graph export: CSV (wide or long), TSV, JSON Lines, JSON, .sfplot
  • Export a selected range only
  • Import CSV, JSON, SQLite recordings and sessions back as overlay layers
  • Device commands (opt-in): save a graph or the log, start and stop logging and recording, from the firmware
SerialFlow window recording, with live sample counts per storage format.
Record every signal into one dataset: SQLite, CSV and JSON Lines. How it was done →
Reopened temperature graph from a saved plot session.
Save a session, reopen it later, or send it to a colleague. How it was done →

Make it yours

26 colour profiles, and every button where you want it.

Six SerialFlow windows showing the same log in different colour themes.
26 built-in colour profiles, or make your own. How it was done →

Pick one of 26 built-in colour profiles, from Dark and Light to Solarized, Nord and Dracula, or edit every colour with a live preview. Each graph has a matching style. Show, hide and colour every toolbar button, rearrange the ☰ menu, and rebind the shortcuts. Save the whole setup as a profile and switch between setups in one step.

  • 26 colour profiles, each with a matching graph style
  • Toolbar and ☰ menu customisation
  • 16 rebindable shortcuts, plus a separate key table for the graphs
  • 17 settings pages, nearly all stored per profile
  • Profiles: new, duplicate, import, export
Keyboard shortcuts table.
Rebind every shortcut.

Timestamps and line numbers

Time it in SerialFlow, in the firmware, or both.

Every line can carry a time and a number from two places: SerialFlow’s clock on the PC, and your board’s own. Use either one, or both side by side, and a mismatch shows at a glance.

In SerialFlow. It notes the time each line arrives and counts the lines. Two tick boxes, both off at first:

  • Settings → Terminal → Show Timestamps, in a format you choose (HH:mm:ss.fff at first, yyyy-MM-dd HH:mm:ss and others work too)
  • Settings → Behavior → Show Line Numbers

Switch them on or off whenever you like: the lines already on screen get them too, because SerialFlow keeps every line’s arrival time.

In your firmware. Print the board’s own time since boot, a tick count or a sequence number at the start of each line. SerialFlow shows it like any other text, in colour if your firmware uses ANSI codes.

Both. Turn on SerialFlow’s columns as well, and every line carries two clocks that check each other.

Compact SerialFlow window: a grey timestamp column and line numbers 1 to 35 beside the MDX-400 boot and run log, which has no time of its own.
SerialFlow’s time and line numbers, switched on in Settings. The firmware sent only the text.

Two clocks, side by side

SerialFlow log with SerialFlow's timestamp and line number columns on the left and the motor drive's own time since boot in brackets at the start of each line.
Left: SerialFlow’s arrival time and line number. In brackets: the drive’s own time since boot. This demo log is replayed at a fixed pace, so the two clocks disagree on purpose: a 40-minute run arrives in six seconds. How it was done →
  • A lost line. The firmware’s numbers skip one (41, then 43) while SerialFlow’s run on without a gap.
  • Delays and bursts. Lines the board sent 100 ms apart arrive in clumps with the same PC time: something on the way held them back, such as an adapter’s latency timer or a busy task.
  • A reset. The board’s clock jumps back to zero while the log scrolls on.
  • Clock drift. Over a long run, the board’s time and the PC’s slowly drift apart: the board’s oscillator against the PC’s clock.
  • In the log file too. The .csv log adds the time each line arrived and its number in the file, and the .txt log can start each line with the time; the firmware’s own stamp stays in the text.
  • Clean copies. Copy leaves SerialFlow’s columns out, and so does the .txt log unless you ask for the time, so what you paste is exactly what the board sent.

Built for the bench

Long runs, unplugged cables, several ports.

  • Several ports at once

    Each port gets its own workspace with its own terminal, graphs and tools. The Data Collector records them all in one run.

  • Hot-plug and auto-reconnect

    Pull the USB cable, plug it back in, and the session reconnects, under a new COM number too if the device has a USB serial number. A deliberate Disconnect stays disconnected.

  • Sleep and wake

    After the laptop wakes, SerialFlow re-scans the ports and reconnects on its own.

  • FTDI latency timer

    Optionally lower it from 16 ms to as little as 1 ms for snappier graphs. The original value is restored on close. Needs administrator rights; without them, the status bar says the old value was kept.

  • Modem lines

    The Signal Lines pane shows CTS, DSR, DCD and RI and switches DTR and RTS. A USB board that stays silent because it waits for DTR gets a hint after 3 s.

  • Plain error messages

    A port another program holds says “COM5 is in use by another program”, and one that has gone says it does not exist or was unplugged.

  • Long-term logging

    Run for days, keeping the newest lines by count, by age or by memory, while auto-log writes rotating files.

  • Baud rates

    9 600 to 3 000 000 baud. Settings → Max baud shortens the list to what your adapter can do.

Animation: SerialFlow with two ports side by side: the MDX-400 drive log on COM1 in an orange tab on the left and the BMS pack log on COM11 in a green tab on the right, both filling at the same time.
Two ports at once, each with its own terminal and colour: the motor drive on COM1, the battery pack monitor on COM11.

Arrange it your way

Drag a tab onto the dock guide to put any view beside another, under it, or out in a window of its own. The arrangement is saved with the profile.

Know which port is which

With a handful of adapters plugged in, COM numbers stop meaning much. The port list shows each COM number with the adapter’s own name, and Port Details (☰ → Tools) tells you the rest. Copy All copies it, ready for a bug report.

  • Every port: the chip (FTDI, CH340, CP210x, PL2303 …), VID:PID, serial number, manufacturer, driver version and the Windows device IDs
  • FTDI adapters get a tab of their own: each one’s factory serial number, USB location and latency timer, and the FTDI driver versions. Two identical FTDI cables are told apart by serial number, and Connect by Serial # connects to the one you pick
  • Snappier FTDI: lower the latency timer from 16 ms to as little as 1 ms (needs administrator rights); the original comes back when the port closes
  • Serial numbers in the port list too, with Settings → Diagnostics → Port Dropdown: Extensive

Why serial numbers matter. Windows gives each adapter a COM number the first time it sees it. An adapter with its own serial number, like an FTDI cable, keeps that number in any USB socket. One without (many CH340 boards, for example) can get a new number in every socket, so on a busy bench the numbers keep shifting. SerialFlow remembers the USB serial number of the device behind each port. When that device turns up under another COM number, for example on another PC or after a driver reinstall, SerialFlow finds it at start-up, when it is plugged in and after sleep, connects there and says so in the status bar. A board without a serial number is still remembered by its COM number.

Port Details window, Port Detail tab: an STMicroelectronics ST-Link virtual COM port with its friendly name, VID:PID, manufacturer, driver version and device IDs.
Port Details: the adapter behind a COM port, down to its driver and device IDs.

By the numbers

Small window, deep toolbox.

graphs per port × signals per graph
26 × 32
plus computed signals
dashboard widget types
67
in 8 groups
lines of scrollback
100 000
default; configurable
colour profiles
26
each with a matching graph style
checksum and hash algorithms
12
CRC, sums, MD5, SHA
graph export formats
6
CSV wide/long, TSV, JSON Lines, JSON, .sfplot

Get started

Try it in one minute, without hardware.

The installer comes with demo files: the simulated MDX-400 motor-drive bench run that every picture on this page shows. On the first start SerialFlow copies them to Documents\SerialFlow\Demo.

  1. Install and start SerialFlow. You don’t need to connect a port.
  2. ☰ → Test → Load Test File → Demo → showcase_preload.txt. Four graphs, the coloured log and two status windows appear.
  3. ☰ → Test → Delayed Playback → Demo → showcase_live.txt. The run continues live for about 1 min 50 s.

More scenes (oscilloscope, noisy link, canvas dashboard, run comparison) are listed in Demo\README.txt.

From your own firmware

Or let an AI assistant write it: give it the AI reference and describe your board.

A coloured log

Print ANSI codes as usual:

printf("\x1B[32m[ OK ]\x1B[0m ADC calibrated\n");
printf("\x1B[33m[WARN]\x1B[0m MOSFET 72.4 C\n");

How the MDX-400 log was done →

A status window

Updates in place, in window 1:

printf("~ClA1:\n");                          // clear window 1
printf("~WrLi1:0:Drive status\n");
printf("~WrLi1:1:Speed   %4d rpm\n", rpm);   // later, ~UpLi1:1:... rewrites only this line

How the MDX-400 status windows were done →

A graph (Arduino; any MCU with a UART works the same way)

void setup() {
    Serial.begin(115200);
    Serial.println("~{A:I:Sensors:500:S:T:F:Sample::0}");
    Serial.println("~{A:S:1:F32:R:Temperature:C:0:FF6644}");
    Serial.println("~{A:S:2:F32:R:Humidity:%:0:44AAFF}");
    Serial.println("~{A:H:1:30.0:FF4444:D:High Temp}");   // a red limit line at 30 °C
}

void loop() {
    Serial.print("~{A:1:");
    Serial.print(readTemperature(), 1);
    Serial.print(":");
    Serial.print(readHumidity(), 1);
    Serial.println("}");
    delay(100);
}

Tips: put one ~{…} command per line, at the start of the line. The auto-X data command (1), as above, numbers the samples for you; 0 sends your own X first. How the MDX-400 graphs were done →

Requirements and download

One installer. Nothing else to install.

WindowsWindows 11, 64-bit (x64). Windows 10 should work but has not been tested yet
.NETNothing to install: the .NET 8 runtime is built into the app
InstallerSerialFlow-win-Setup.exe from GitHub Releases; installs for the current user in %LocalAppData%\SerialFlow
UpdatesSerialFlow checks for a new version at start-up and updates itself in one click
PriceFree to use, for personal and commercial work
Serial hardwareAny device Windows shows as a COM port: on-board UARTs, USB-serial adapters and USB-CDC boards
Baud rates9 600 to 3 000 000 (11 standard rates)
Administrator rightsOnly for the optional FTDI latency-timer setting
Your settingsDocuments\SerialFlow and %APPDATA%\SerialFlow

Download SerialFlow 0.9.0 beta 2All releases

Feedback, licence and privacy

It’s a pre-release: tell us what you find.

SerialFlow is a pre-release, and it needs testers. Install it, connect your boards, try to break it, and have fun with it. If something breaks, looks wrong or is missing, open an issue on GitHub; a free account is enough. Bug reports with a few lines of the serial output that cause the problem are the most useful. Where SerialFlow comes from →

Report a bugSuggest a feature

Licence

Free to use, for personal and commercial work: that has been the plan from the start. SerialFlow is not open source: please share the link rather than the installer. Full licence · Third-party notices

Privacy

SerialFlow checks lizerd.se for new versions; you can turn this off. If you agree, it also sends one anonymous count a day (app version, Windows version, minutes used). It has no ID, no personal data and nothing about your devices or data. Privacy details

Questions

FAQ

Do I need to change my firmware?

No. SerialFlow is a normal serial terminal: anything your device prints appears in the log, ANSI colours included. You only add the short ~{…} lines if you want graphs, and ~WrLi lines if you want status windows.

Do I need a library on the microcontroller?

No. The graph and status commands are plain text, so printf or Serial.print is enough.

Can an AI assistant write the firmware side for me?

Yes. Download the AI reference, one Markdown file, attach it to a chat with your assistant and describe your board. It holds every command and setting, the rules, tested code for common microcontrollers and what this beta can’t do yet.

What hardware works?

Anything that appears as a COM port in Windows: USB-serial adapters (FTDI, CH340, CP210x, …), USB-CDC boards (ST-Link, Arduino, ESP32, …), debug probes with a virtual COM port, and on-board UARTs.

How fast can it go?

Up to 3 000 000 baud, if your adapter supports it. SerialFlow itself is not the limit: its parser and log take 30 to 130 MB/s on one core of a desktop PC, while a 3 Mbaud link carries 0.3 MB/s. For high-rate graph data there is a packed binary mode: COBS-framed packets with a CRC-8, many samples per packet.

Can I check the data's integrity?

Yes. Graph lines can carry an optional CRC-8. Lines that fail are dropped from the graph and listed in the RX Error Collector with the reason.

Can I use the data in Excel, Python or MATLAB?

Yes. Export a graph as CSV (wide or long), TSV, JSON Lines or JSON, or record everything with the Data Collector to SQLite, CSV or JSON Lines.

Can I share my setup with a colleague?

Yes. Export your profile, or send a .sfplot session, which holds the data, the notes and the view in one file.

Does it work offline? Does it send my data anywhere?

It works fully offline. Your serial data, logs and settings never leave your PC. Online, SerialFlow checks lizerd.se for a newer version (you can turn this off). Only if you agree, it also sends one anonymous count a day: app version, Windows version and minutes used, with no ID. See Privacy.

How much does it cost?

Nothing. The plan has always been for SerialFlow to be free to use, at home and at work. What the future brings, time will tell. Where SerialFlow comes from.

Is it open source?

No. It is free to use, but the source code is not public. Please share the link to this page rather than the installer, so everyone gets the updates.

Which Windows versions?

Windows 11, 64-bit. Windows 10 (64-bit) should work but has not been tested yet. If you try it, please tell us on GitHub.

Windows says “Windows protected your PC”. Is that safe?

The pre-release installer is not code-signed yet, so Windows cannot confirm who made it, and SmartScreen does not recognise it. Click More info → Run anyway. Only download it from this page or from github.com/Lizerd/SerialFlow-Releases; the release notes there give its SHA-256 fingerprint to check with Get-FileHash.

Windows says “Smart App Control blocked an app that may be unsafe”. What now?

Smart App Control (Windows 11) blocks programs that are not code-signed, and this pre-release is not, so there is no button to go on. The only way is to turn Smart App Control off (Windows Security → App & browser control). We do not ask you to: that removes the protection for every program on the PC, not only SerialFlow, and on many PCs it cannot be turned on again without resetting Windows. The safe choice is to wait for a signed version (planned, no date yet). If Smart App Control is in Evaluation mode, Windows may switch it on later, and then it may stop an installed SerialFlow from starting. More in the manual.

The SerialFlow window stays blank or white. What now?

On some PCs every WPF window stays blank with hardware graphics, SerialFlow’s included. Press Win+R and run "%LocalAppData%\SerialFlow\current\SerialFlow.App.exe" --software, then tick Settings → About → Use software rendering. From the next start SerialFlow draws without the graphics card on that PC. More in the manual.

How do I update?

SerialFlow tells you at start-up when a new version is out, and updates itself when you click Install and restart. You can also download the latest installer from this page.

How do I report a bug or ask for a feature?

Open an issue on GitHub. A free GitHub account is enough. Please include the SerialFlow version (Settings → About), your Windows version and your serial adapter.

Why “pre-release”?

SerialFlow works, but it hasn’t been tested widely yet. These are its first releases, so expect a few rough edges, and expect frequent updates. Every report you send makes the next one better.